Mercurial > repos > lecorguille > xcms_summary
view test-data/faahKO.xset.group.retcor.group.fillpeaks.summary.html @ 12:27e7da5f6848 draft
planemo upload for repository https://github.com/workflow4metabolomics/xcms commit a6f5f18b3d6130f7d7fbb9f2df856838c6217797
author | lecorguille |
---|---|
date | Fri, 07 Apr 2017 07:37:23 -0400 |
parents | |
children | 97ca0321931b |
line wrap: on
line source
<!DOCTYPE html> <HTML lang='en'> <HEAD> <meta http-equiv='Content-Type' content='text/html; charset=UTF-8' /> <title>[W4M] XCMS analysis summary</title> <style> table, tr, td, th { border: 1px solid #000000; border-collapse:collapse; } td,th { padding: 5px; padding-right: 12px; } th { background: #898989; text-align:left;color: white;} h2 { color: #FFA212; } ul li { margin-bottom:10px; } </style> </HEAD> <BODY> <div><h1>___ XCMS analysis summary using Workflow4Metabolomics ___</h1> </div> <h2>Samples used:</h2> <div><table> <tr><th>sample</th><th>filename</th><th>md5sum<sup>*</sup></th></tr> <tr> <td> ko15 </td> <td> faahKO_reduce/KO/ko15.CDF </td> <td> 4698c36c0b3af007faf70975c04ccf2a </td> </tr><tr> <td> ko16 </td> <td> faahKO_reduce/KO/ko16.CDF </td> <td> afaeed94ced3140bc042d5ab6aeb16c1 </td> </tr><tr> <td> wt15 </td> <td> faahKO_reduce/WT/wt15.CDF </td> <td> d58a27fad7c04ddddb0359ddc2b7ba68 </td> </tr><tr> <td> wt16 </td> <td> faahKO_reduce/WT/wt16.CDF </td> <td> 29654e9f8ad48c1fbe2a41b9ba578f6e </td> </tr> </table> <br/><sup>*</sup>The program md5sum is designed to verify data integrity. So you can check if the data were uploaded correctly or if the data were changed during the process. </div> <h2>Function launched:</h2> <div><table> <tr><th>timestamp<sup>***</sup></th><th>function</th><th>argument</th><th>value</th></tr> <tr><td rowspan='4'>160420-14:09:46</td><td rowspan='4'>xcmsSet</td> <td>nSlaves</td><td>1</td></tr> <tr><td>method</td><td>centWave</td></tr> <tr><td>ppm</td><td>25</td></tr> <tr><td>peakwidth</td><td>2050</td></tr> <tr><td rowspan='6'>160420-15:07:14</td><td rowspan='6'>group</td> <td>method</td><td>density</td></tr> <tr><td>sleep</td><td>0.001</td></tr> <tr><td>minfrac</td><td>0.3</td></tr> <tr><td>bw</td><td>5</td></tr> <tr><td>mzwid</td><td>0.01</td></tr> <tr><td>max</td><td>50</td></tr> <tr><td rowspan='7'>160421-11:10:32</td><td rowspan='7'>retcor</td> <td>method</td><td>peakgroups</td></tr> <tr><td>smooth</td><td>loess</td></tr> <tr><td>extra</td><td>1</td></tr> <tr><td>missing</td><td>1</td></tr> <tr><td>span</td><td>0.2</td></tr> <tr><td>family</td><td>gaussian</td></tr> <tr><td>plottype</td><td>deviation</td></tr> <tr><td rowspan='6'>160421-11:19:31</td><td rowspan='6'>group</td> <td>method</td><td>density</td></tr> <tr><td>sleep</td><td>0.001</td></tr> <tr><td>minfrac</td><td>0.3</td></tr> <tr><td>bw</td><td>5</td></tr> <tr><td>mzwid</td><td>0.01</td></tr> <tr><td>max</td><td>50</td></tr> <tr><td rowspan='1'>160421-11:50:48</td><td rowspan='1'>fillPeaks</td> <td>method</td><td>chrom</td></tr> </table> <br/><sup>***</sup>timestamp format: yymmdd-hh:mm:ss </div> <h2>Informations about the xcmsSet object:</h2> <div><pre> An "xcmsSet" object with 4 samples Time range: 2506-4484 seconds (41.8-74.7 minutes) Mass range: 200.1-600 m/z Peaks: 32720 (about 8180 per sample) Peak Groups: 8157 Sample classes: KO, WT Profile settings: method = bin step = 0.1 Memory usage: 4.25 MB </pre></div> <h2>Citations:</h2> <div><ul> <li>To cite the <b>XCMS</b> package in publications use: <ul> <li>Smith, C.A. and Want, E.J. and O'Maille, G. and Abagyan,R. and Siuzdak, G.XCMS: Processing mass spectrometry data for metabolite profiling using nonlinear peak alignment, matching and identification, Analytical Chemistry, 78:779-787 (2006)</li> <li>Ralf Tautenhahn, Christoph Boettcher, Steffen Neumann: Highly sensitive feature detection for high resolution LC/MS BMC Bioinformatics, 9:504 (2008)</li> <li>H. Paul Benton, Elizabeth J. Want and Timothy M. D. Ebbels Correction of mass calibration gaps in liquid chromatography-mass spectrometry metabolomics data Bioinformatics, 26:2488 (2010)</li> </ul> </li> <li>To cite the <b>CAMERA</b> package in publications use: <ul> <li>Kuhl, C., Tautenhahn, R., Boettcher, C., Larson, T. R. and Neumann,S. CAMERA: an integrated strategy for compound spectra extraction and annotation of liquid chromatography/mass spectrometry data sets. Analytical Chemistry, 84:283-289 (2012)</li> </ul> </li> <li>To cite the <b>Workflow4Metabolimics (W4M)</b> project in publications use: <ul> <li>Franck Giacomoni, Gildas Le Corguillé, Misharl Monsoor, Marion Landi, Pierre Pericard, Mélanie Pétéra, Christophe Duperier, Marie Tremblay-Franco, Jean-François Martin, Daniel Jacob, Sophie Goulitquer, Etienne A. Thévenot and Christophe Caron (2014). Workflow4Metabolomics: A collaborative research infrastructure for computational metabolomics. Bioinformatics doi:10.1093/bioinformatics/btu813</li> </ul> </li> </ul></div> </BODY> </HTML>