Mercurial > repos > lecorguille > xcms_xcmsset
view macros_xcms.xml @ 33:f5d51091cf84 draft
planemo upload for repository https://github.com/workflow4metabolomics/tools-metabolomics/ commit 2cb157bd9a8701a3d6874e084032cbd050b8953e
author | workflow4metabolomics |
---|---|
date | Mon, 11 Sep 2023 09:22:36 +0000 |
parents | b02d1992a43a |
children |
line wrap: on
line source
<?xml version="1.0"?> <macros> <token name="@TOOL_VERSION@">3.12.0</token> <token name="@VERSION_SUFFIX@">1</token> <token name="@PROFILE@">21.09</token> <xml name="requirements"> <requirements> <requirement type="package" version="@TOOL_VERSION@">bioconductor-xcms</requirement> <requirement type="package" version="1.1_5">r-batch</requirement> <requirement type="package" version="1.1_2">r-rcolorbrewer</requirement> <requirement type="package" version="6.0">unzip</requirement> <yield /> </requirements> </xml> <!-- FILE_LOAD for planemo test --> <token name="@COMMAND_FILE_LOAD@"> #if $file_load_section.file_load_conditional.file_load_select == "yes": #if $file_load_section.file_load_conditional.input[0].is_of_type("mzxml") or $file_load_section.file_load_conditional.input[0].is_of_type("mzml") or $file_load_section.file_load_conditional.input[0].is_of_type("mzdata") or $file_load_section.file_load_conditional.input[0].is_of_type("netcdf"): #set singlefile_galaxyPath = '|'.join( [ str( $single_file ) for $single_file in $file_load_section.file_load_conditional.input ] ) #set singlefile_sampleName = '|'.join( [ str( $single_file.element_identifier ) for $single_file in $file_load_section.file_load_conditional.input ] ) singlefile_galaxyPath '$singlefile_galaxyPath' singlefile_sampleName '$singlefile_sampleName' #else zipfile '$file_load_section.file_load_conditional.input' #end if #end if </token> <xml name="input_file_load"> <section name="file_load_section" title="Resubmit your raw dataset or your zip file"> <conditional name="file_load_conditional"> <param name="file_load_select" type="select" label="Resubmit your dataset or your zip file" help="Use only if you get a message saying that your original dataset or zip file have been deleted on the server." > <option value="no" >no need</option> <option value="yes" >yes</option> </param> <when value="no"> </when> <when value="yes"> <param name="input" type="data" format="mzxml,mzml,mzdata,netcdf,zip" multiple="true" label="File(s) from your history containing your chromatograms" help="Single file mode for the format: mzxml, mzml, mzdata and netcdf. Zip file mode for the format: zip. See the help section below." /> </when> </conditional> </section> </xml> <xml name="test_file_load_zip"> <section name="file_load_section"> <conditional name="file_load_conditional"> <param name="file_load_select" value="yes" /> <param name="input" value="faahKO_reduce.zip" ftype="zip" /> </conditional> </section> </xml> <xml name="test_file_load_zip_sacuri"> <section name="file_load_section"> <conditional name="file_load_conditional"> <param name="file_load_select" value="yes" /> <param name="input" value="sacuri_dir_root.zip" ftype="zip" /> </conditional> </section> </xml> <xml name="test_file_load_single"> <section name="file_load_section"> <conditional name="file_load_conditional"> <param name="file_load_select" value="yes" /> <param name="input" value="wt15.CDF,ko16.CDF,ko15.CDF,wt16.CDF" ftype="netcdf" /> </conditional> </section> </xml> <xml name="test_file_load_single_file" token_filename=""> <section name="file_load_section"> <conditional name="file_load_conditional"> <param name="file_load_select" value="yes" /> <param name="input" value="@FILENAME@.CDF" ftype="netcdf" /> </conditional> </section> </xml> <!-- PEAKLIST --> <token name="@COMMAND_PEAKLIST@"> #if $peaklist.peaklistBool == 'true' convertRTMinute $peaklist.convertRTMinute numDigitsMZ $peaklist.numDigitsMZ numDigitsRT $peaklist.numDigitsRT intval $peaklist.intval naTOzero $peaklist.naTOzero #end if </token> <xml name="input_peaklist"> <param name="convertRTMinute" type="boolean" checked="false" truevalue="TRUE" falsevalue="FALSE" label="Convert retention time (seconds) into minutes" help="Convert the columns rtmed, rtmin and rtmax into minutes"/> <param name="numDigitsMZ" type="integer" value="4" label="Number of decimal places for mass values reported in ions' identifiers." help="A minimum of 4 decimal places is recommended. Useful to avoid duplicates within identifiers" /> <param name="numDigitsRT" type="integer" value="0" label="Number of decimal places for retention time values reported in ions' identifiers." help="Useful to avoid duplicates within identifiers" /> <param name="intval" type="select" label="Reported intensity values" help="[intval] See the help section below"> <option value="into" selected="true">into</option> <option value="maxo">maxo</option> <option value="intb">intb</option> </param> <param name="naTOzero" type="boolean" checked="true" truevalue="TRUE" falsevalue="FALSE" label="If NA values remain, replace them by 0 in the dataMatrix" help="Mandatory for some of the downstream tools (data processing, statistics) that do not accept NA values"/> </xml> <xml name="input_peaklist_section"> <section name="peaklist" title="Peak List" expanded="True"> <param name="peaklistBool" type="hidden" label="Get the Peak List" value="true" /> <expand macro="input_peaklist"/> </section> </xml> <xml name="input_peaklist_conditional"> <conditional name="peaklist"> <param name="peaklistBool" type="select" label="Get the Peak List"> <option value="true">Yes</option> <option value="false">No</option> </param> <when value="true"> <expand macro="input_peaklist"/> </when> <when value="false" /> </conditional> </xml> <xml name="output_peaklist" token_function=""> <data name="variableMetadata" format="tabular" label="${image.name[:-6]}.@FUNCTION@.variableMetadata.tsv" from_work_dir="variableMetadata.tsv" > <filter>peaklist['peaklistBool'] == 'true'</filter> </data> <data name="dataMatrix" format="tabular" label="${image.name[:-6]}.@FUNCTION@.dataMatrix.tsv" from_work_dir="dataMatrix.tsv" > <filter>peaklist['peaklistBool'] == 'true'</filter> </data> </xml> <token name="@HELP_PEAKLIST@"> Get a Peak List --------------- If 'true', the module generates two additional files corresponding to the peak list: - the variable metadata file (corresponding to information about extracted ions such as mass or retention time) - the data matrix (corresponding to related intensities) **decimal places for [mass or retention time] values in identifiers** | Ions' identifiers are constructed as MxxxTyyy where 'xxx' is the ion median mass and 'yyy' the ion median retention time. | Two parameters are used to adjust the number of decimal places wanted in identifiers for mass and retention time respectively. | Theses parameters do not affect decimal places in columns other than the identifier one. **Reported intensity values** | This parameter determines which values should be reported as intensities in the dataMatrix table; it correspond to xcms 'intval' parameter: | - into: integrated area of original (raw) peak | - maxo: maximum intensity of original (raw) peak | - intb: baseline corrected integrated peak area (only available if peak detection was done by ‘findPeaks.centWave’) </token> <token name="@HELP_PEAKLIST_OUTPUT@"> xset.variableMetadata.tsv : tabular format | Table containing information about ions; can be used as one input of **Quality_Metrics** or **Generic_filter** modules. xset.dataMatrix.tsv : tabular format | Table containing ions' intensities; can be used as one input of **Quality_Metrics** or **Generic_filter** modules. </token> <!-- CENTWAVE --> <token name="@COMMAND_CENTWAVE@"> ppm $methods.ppm peakwidth "c($methods.peakwidth)" ## Advanced snthresh $methods.CentWaveAdv.snthresh prefilter "c($methods.CentWaveAdv.prefilter)" mzCenterFun $methods.CentWaveAdv.mzCenterFun integrate $methods.CentWaveAdv.integrate mzdiff $methods.CentWaveAdv.mzdiff fitgauss $methods.CentWaveAdv.fitgauss noise $methods.CentWaveAdv.noise verboseColumns $methods.CentWaveAdv.verboseColumns </token> <xml name="input_centwave"> <param argument="ppm" type="float" value="25" label="Max tolerated ppm m/z deviation in consecutive scans in ppm" help="for the initial ROI definition." /> <param argument="peakwidth" type="text" value="20,50" label="Min,Max peak width in seconds" help="with the expected approximate peak width in chromatographic space."> <expand macro="input_validator_range_float"/> </param> </xml> <xml name="input_centwaveAdv"> <param argument="snthresh" type="integer" value="10" label="Signal to Noise ratio cutoff" /> <param argument="prefilter" type="text" value="3,100" label="Prefilter step for for the first analysis step (ROI detection)" help="Separate by coma k, I. Mass traces are only retained if they contain at least ‘k‘ peaks with intensity ‘>= I‘."> <expand macro="input_validator_range_integer"/> </param> <param argument="mzCenterFun" type="select" label="Name of the function to calculate the m/z center of the chromatographic peak" > <option value="wMean">intensity weighted mean of the peak's m/z values</option> <option value="mean">mean of the peak's m/z values</option> <option value="apex">use the m/z value at the peak apex</option> <option value="wMeanApex3">intensity weighted mean of the m/z value at the peak apex and the m/z values left and right of it</option> <option value="meanApex3">mean of the m/z value of the peak apex and the m/z values left and right of it</option> </param> <param argument="integrate" type="select" label="Integration method" > <option value="1">peak limits are found through descent on the mexican hat filtered data (more robust, but less exact)</option> <option value="2">peak limits based on real data (more accurate but prone to noise)</option> </param> <param argument="mzdiff" type="float" value="-0.001" label="Minimum difference in m/z for peaks with overlapping retention times" help="can be negative to allow overlap" /> <param argument="fitgauss" type="boolean" checked="false" truevalue="TRUE" falsevalue="FALSE" label="fitgauss" help="whether or not a Gaussian should be fitted to each peak" /> <param argument="noise" type="integer" value="0" label="Noise filter" help="allowing to set a minimum intensity required for centroids to be considered in the first analysis step (centroids with intensity lower than ‘noise’ are omitted from ROI detection)." /> <param argument="verboseColumns" type="boolean" checked="false" truevalue="TRUE" falsevalue="FALSE" label="verbose Columns" help="whether additional peak meta data columns should be returned" /> </xml> <token name="@COMMAND_CENTWAVEADVROI@"> #if $sectionROI.roiList: roiList '$sectionROI.roiList' firstBaselineCheck $sectionROI.firstBaselineCheck #if $sectionROI.roiScales != "": roiScales "c($sectionROI.roiScales)" #end if #end if </token> <xml name="input_centwaveAdvROI" token_optional="true"> <param argument="roiList" type="data" format="tabular" optional="@OPTIONAL@" label="List of regions-of-interest (ROI) representing detected mass traces" help="If ROIs are submitted the first analysis step is omitted and chromatographic peak detection is performed on the submitted ROIs. Each ROI is expected to have the following elements specified: ‘scmin’ (start scan index), ‘scmax’ (end scan index), ‘mzmin’ (minimum m/z), ‘mzmax’ (maximum m/z), ‘length’ (number of scans), ‘intensity’ (summed intensity)." /> <param argument="firstBaselineCheck" type="boolean" checked="true" truevalue="TRUE" falsevalue="FALSE" label="Is continuous data within regions of interest is checked to be above the first baseline." /> <param argument="roiScales" type="text" value="" optional="true" label="Numeric vector defining the scale for each region of interest in ‘roiList’" help="Length equal to ‘roiList’ - Should be used for the centWave-wavelets (format 0.9,1,0.2)"> <expand macro="input_validator_range_float"/> </param> </xml> <!-- MISC --> <token name="@HELP_AUTHORS@"> .. class:: infomark **Authors** Colin A. Smith csmith@scripps.edu, Ralf Tautenhahn rtautenh@gmail.com, Steffen Neumann sneumann@ipb-halle.de, Paul Benton hpaul.benton08@imperial.ac.uk and Christopher Conley cjconley@ucdavis.edu @HELP_AUTHORS_WRAPPERS@ --------------------------------------------------- </token> <token name="@HELP_XCMS_MANUAL@"> For details and explanations concerning all the parameters and workflow of xcms_ package, see its manual_ and this example_ .. _xcms: https://bioconductor.org/packages/release/bioc/html/xcms.html .. _manual: http://www.bioconductor.org/packages/release/bioc/manuals/xcms/man/xcms.pdf .. _example: https://bioconductor.org/packages/release/bioc/vignettes/xcms/inst/doc/xcms.html .. _news: https://bioconductor.org/packages/release/bioc/news/xcms/NEWS </token> <token name="@HELP_XCMS_NEWVERSION_3440@"> **Version 3.4.4.0 - 08/02/2019** - UPGRADE: upgrade the xcms version from 3.0.0 to 3.4.4 (see XCMS news_) </token> <token name="@HELP_XCMS_NEWVERSION_3610@"> **Version 3.6.1+galaxy* - 03/09/2019** - UPGRADE: upgrade the xcms version from 3.4.4 to 3.6.1 (see XCMS news_) </token> <token name="@HELP_XCMS_NEWVERSION_31200@"> **Version 3.12.0+galaxy* - 03/03/2020** - UPGRADE: upgrade the xcms version from 3.6.1 to 3.12.0 (see XCMS news_) </token> <xml name="citation"> <citations> <citation type="doi">10.1021/ac051437y</citation> <expand macro="citation_w4m"/> </citations> </xml> </macros>