| 1 parameter,Value,Description | |
| 2 ,, | |
| 3 Experimental Design,, | |
| 4 Experiment,experiment_lc,"Experiment name, no spaces." | |
| 5 Species,mus musculus,Genus species from which samples are derived. | |
| 6 Sample,serum,"Type of sample (e.g., serum, leaf)." | |
| 7 Contributer,recetox,Your or your PI's name. | |
| 8 platform,LC-MS,Either GC-MS or LC-MS. | |
| 9 ,, | |
| 10 GC-MS,, | |
| 11 chrominst,fill,Model of LC/GC instrument. | |
| 12 msinst,fill,Model of MS instrument. | |
| 13 column,fill,Column description. | |
| 14 InletTemp,fill,Temperature of inlet. | |
| 15 TransferTemp,fill,Temperature of GC to MS transfer line. | |
| 16 mstype,fill,"Type of mass spectrometer (one of QQQ, TOF, QTOF, Orbi, Q)." | |
| 17 msmode,fill,Positive or negative ion mode. | |
| 18 ionization,fill,"Ionization (EI, AP, or CI)." | |
| 19 msscanrange,fill,Scan range used for acquisition. | |
| 20 scantime,fill,Time for each full scan spectrum (e.g. 0.2 seconds). | |
| 21 deriv,fill,"Derivitization (TMS, TBDMS, or None)." | |
| 22 MSlevs,fill,Number of levels of energy acquired - 1 typically. | |
| 23 ,, | |
| 24 LC-MS,, | |
| 25 chrominst,UltiMateX 3000 BioRS System,Model of LC/GC instrument. | |
| 26 msinst,FSN04-10000,Model of MS instrument. | |
| 27 column,These columns enable analysis of ppm levels of amines without column priming,Column description. | |
| 28 solvA,H20,Solvent A composition. | |
| 29 solvB,CO2,Solvent B composition. | |
| 30 CE1,50,Collision energy of acquisition of MS data. | |
| 31 CE2,100,Collision energy of acquisition for MSe/idMSMS data (when applicable). | |
| 32 mstype,Q,"Type of mass spectrometer (one of QQQ, TOF, QTOF, Orbi, Q)." | |
| 33 msmode,negative,Positive or negative ion mode. | |
| 34 ionization,ESI,"Ionization (EI, AP, or CI)." | |
| 35 colgas,He,Gas used for collisional dissociation. | |
| 36 msscanrange,1000,Scan range used for acquisition. | |
| 37 conevol,12,Cone voltage used for acquisition. | |
| 38 MSlevs,1.0,Number of levels of energy acquired - 1 typically. |